Abstract

Plasma B-type natriuretic peptide (BNP) is a practical tool with which to estimate hemodynamic status including intra-cardiac pressure in patients with heart failure (HF). However, plasma BNP levels cannot be measured immediately in an outpatient private clinic. We investigated the value of remote dielectric sensing (ReDS), a novel non-invasive electromagnetic energy-based tool to quantify lung fluid amount immediately, to predict plasma BNP levels.Successive measurements of ReDS values and plasma BNP levels were performed in patients hospitalized to treat HF in a prospective manner. Correlations between ReDS values and plasma BNP levels were assessed.A total of 117 datasets for HF patients were obtained in this prospective study. The median ReDS value was 28% (interquartile range: 25%, 34%) and the median plasma BNP level was 205 (86, 469) pg/mL, both of which had a slight correlation (r = 0.234, P = 0.011). Their correlation improved when those with a body mass index less than 18.5 (n = 23) were excluded (r = 0.278, P = 0.007).ReDS might be a practical tool for estimating plasma BNP levels, particularly in outpatient private clinics where the immediate measurement of plasma BNP levels is not available.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.