Abstract

The high-voltage DC flashover characteristics of a large number of solid insulating materials were investigated. These materials included high-density aluminas from different manufacturers varying in bulk composition and surface microstructure, coated aluminas to reduce surface charging, steatite, and forsterite. The results show a strong correlation between the first and conditioned breakdown strengths, the rapidity of conditioning, and the surface microstructure. Specifically, it is shown that 'generic alumina' has widely varying voltage withstand strengths depending on the bulk composition, surface microstructure, and chemical surface state. Materials with a finely granular, closely packed structure exhibited the best voltage hold-off performance. Also, nonporous materials exhibit rapid conditioning to its final value. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.