Abstract

This paper describes the difference on the electrical performance of carbon fiber reinforced composites (CFRCs) when two different Resin Film Infusion (RFI) manufacturing techniques are used. For the panel obtained by bulk infusion the measured in plane and out of plane electrical conductivities were 2.0 × 104 S/m and 3.9 S/m respectively and for the panel prepared using the traditional resin film infusion the values were 1.1 × 104 S/m and 1.7 S/m respectively. Morphological investigations on the sections of etched panels have highlighted that this difference in the electrical conductivity was strictly related to the different distribution of multiwall carbon nanotubes (MWCNTs) between the carbon fibers (CFs) of the plies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.