Abstract

To determine the use of differential pressure difference (DPD), in air-puff differential tonometry, as a potential biomechanical measure of the cornea and elucidate its relationship with the intraocular pressure (IOP), central corneal thickness, corneal curvature, and age. This study comprised 396 eyes from 198 patients and was conducted at Acibadem University, School of Medicine, Department of Ophthalmology, Istanbul, Turkey. The central corneal curvature and refraction of the eyes were measured using an Auto Kerato-Refractometer (KR-1; Topcon Corporation, Tokyo, Japan). IOP and central corneal thickness were measured using a tono-pachymeter (CT-1P; Topcon Corporation, Tokyo, Japan), wherein two separate readings of IOP were obtained using two different modes: 1–30 and 1–60. The difference between these two readings was recorded as the DPD. The factors affecting the DPD were determined by stepwise multiple linear regression analysis. DPD varied over a dynamic range of − 3.0 to + 5.0 mmHg and was weakly correlated with the central corneal thickness (r = 0.115, p < 0.05). DPD showed no significant correlation with IOP 1–30 (p > 0.05). A weak but statistically significant (p < 0.05) positive correlation of DPD was observed with age (r = 0.123), Kavg (r = 0.102), and the CCT (r = 0.115). There was a significant correlation between DPD and Kavg, CCT, and age. There was no significant correlation between DPD and IOP 1–30. Age-related changes in the corneal ultrastructure may be a plausible explanation for the weak positive association between age and DPD. The proposed method may prove a valid non-invasive tool for the evaluation of corneal biomechanics and introduce DPD in the decision-making of routine clinical practice.

Highlights

  • To determine the use of differential pressure difference (DPD), in air-puff differential tonometry, as a potential biomechanical measure of the cornea and elucidate its relationship with the intraocular pressure (IOP), central corneal thickness, corneal curvature, and age

  • The accuracy of the IOP values is negatively influenced by variation in the ocular rigidity (OR)[2] and the Goldmann Tonometry is nonexempt from such elastic ­effects[3]

  • This study determined the use of DPD in air-puff differential tonometry, as a potential biomechanical measure of the cornea and elucidated its relationship with IOP, central corneal thickness, corneal curvature, and age

Read more

Summary

Introduction

To determine the use of differential pressure difference (DPD), in air-puff differential tonometry, as a potential biomechanical measure of the cornea and elucidate its relationship with the intraocular pressure (IOP), central corneal thickness, corneal curvature, and age. IOP and central corneal thickness were measured using a tono-pachymeter (CT-1P; Topcon Corporation, Tokyo, Japan), wherein two separate readings of IOP were obtained using two different modes: 1–30 and 1–60. The difference between these two readings was recorded as the DPD. The accuracy of the IOP values is negatively influenced by variation in the ocular rigidity (OR)[2] and the Goldmann Tonometry is nonexempt from such elastic ­effects[3]

Objectives
Methods
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.