Abstract
The anticipation of recently published European product standards for industrial thermal insulation has driven improvements in high-temperature thermal conductivity measurements in an attempt to obtain overall measurement uncertainties better than 5 % (k = 2). The two measurement issues that are focused on in this article are the effect of thermal expansion on in situ thickness measurement and on determining the metering area at high temperatures. When implementing in situ thickness measurements, it is vital to correct the thermal expansion of components in a high-temperature guarded hot plate (HTGHP). For example, in the NPL HTGHP this could cause 3.2 % measurement error for a 50 mm thick specimen at 800 °C. The thermal expansion data for nickel 201 measured by NPL are presented, and the effect of this on the metering area of NPL’s heater plate (nickel 201) is discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.