Abstract

Background. After penetrating keratoplasty, mild to high induced corneal astigmatism was observed in each case. The existing choice of correction of postkeratoplastic astigmatism is aimed at fi nding an individual approach in order to compensate for it and not weaken the biomechanical properties of the corneal graft.The aim: to analyze the clinical, functional, and morphological results of postkeratoplastic astigmatism correction by implantation of intrastromal corneal segments using a femtosecond laser.Methods. 22 patients were examined before and 1 year after surgery. The operation was performed under local anesthesia: stage I – an intrastromal tunnel was formed using a femtosecond laser “Femto Visum” 1 MHz (Optosystems, Russia); stage II – the intrastromal corneal segments were implanted. The results were assessed using standard and special research methods using optical coherence tomography Visante OCT (Zeiss, Germany), keratotopography (Tomey-5, Japan), optical corneal analyzer ORA (Reichert, USA), laser tindalemetry FC-2000 (Kowa, Japan) and confocal microscope Confoscan-4 (Nidek, Japan).Results. Before the operation, uncorrected visual acuity averaged 0.09 ± 0.05, after a year – 0.50 ± 0.16; best corrected visual acuity – 0.30 ± 0.12 and 0.60 ± 0.05 respectively; cylindrical component of refraction – –10.29 ± 3.12 and –2.20 ± 0.64 D respectively; mean keratometry value – 43.59 ± 2.14 and 38.56 ± 1.75 D respectively; corneal hysteresis – 7.92 ± 1.22 and 8.95 ± 1.05 mm Hg respectively; corneal resistance factor – 7.01 ± 1.81 and 8.44 ± 1.44 mm Hg respectively; protein fl ux in the moisture of the anterior chamber – 2.97 ± 0.28 and 3.04 ± 0.24 f/ms respectively; endothelial cell density – 1521 ± 327 and 1475 ± 419 cells/mm2 respectively.Conclusion. Intrastromal corneal segments implantation into a corneal graft using a femtosecond laser has efficiency and safety method in correcting postkeratoplastic astigmatism.

Highlights

  • induced corneal astigmatism was observed in each case

  • The existing choice of correction of postkeratoplastic astigmatism is aimed at finding an individual approach in order to compensate for

  • The operation was performed under local anesthesia

Read more

Summary

Introduction

Mild to high induced corneal astigmatism was observed in each case. Нами было обследовано 22 пациента (22 глаза) – 10 женщин и 12 мужчин – до и через 1 год после выполнения имплантации ИРС с применением фемтосекундного лазера (ФСЛ) для коррекции посткератопластического астигматизма. 1. Глаз на следующий день после имплантации интрароговичных сегментов в роговичный трансплантат с применением фемтосекундного лазера FIG.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call