Abstract

PurposeInhomogeneous excitation at ultrahigh field strengths (7T and above) compromises the reliability of quantified dynamic contrast‐enhanced breast MRI. This can hamper the introduction of ultrahigh field MRI into the clinic. Compensation for this non‐uniformity effect can consist of both hardware improvements and post‐acquisition corrections. This paper investigated the correctable radiofrequency transmit (B1+) range post‐acquisition in both simulations and patient data for 7T MRI.MethodsSimulations were conducted to determine the minimum B1+ level at which corrections were still beneficial because of noise amplification. Two correction strategies leading to differences in noise amplification were tested. The effect of the corrections on a 7T patient data set (N = 38) with a wide range of B1+ levels was investigated in terms of time‐intensity curve types as well as washin, washout and peak enhancement values.ResultsIn simulations assuming a common amount of T1 saturation, the lowest B1+ level at which the SNR of the corrected images was at least that of the original precontrast image was 43% of the nominal angle. After correction, time‐intensity curve types changed in 24% of included patients, and the distribution of curve types corresponded better to the distribution found in literature. Additionally, the overlap between the distributions of washin, washout, and peak enhancement values for grade 1 and grade 2 tumors was slightly reduced.ConclusionAlthough the correctable range varies with the amount of T1 saturation, post‐acquisition correction for inhomogeneous excitation was feasible down to B1+ levels of 43% of the nominal angle in vivo.

Highlights

  • Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal

  • The B+1 level in the measured map was investigated because the AFI B+1 mapping strategy used is known to have a reliable linear range limited to 50–150% of the nominal angle.[27]

  • In DCE-MRI, the precontrast image usually has the lowest SNR, because it has the lowest amount of signal

Read more

Summary

Introduction

Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal.

Objectives
Results
Discussion
Conclusion