Abstract
OBJECTIVETo verify the behavior of coronary microvascular tone during spontaneous ischemia in patients with unstable angina (UA).BACKGROUNDIn UA, the pathogenetic role of vasoconstriction is classically confined at the stenotic coronary segment. However, microcirculatory vasoconstriction has been also suggested by previous experimental and clinical studies.METHODSThe study included 10 patients with UA (recent worsening of anginal threshold and appearance of angina at rest) and single-vessel CAD. Blood flow velocity was monitored by a Doppler catheter in the diseased artery. Transstenotic pressure gradient was monitored by aortic and distal coronary pressure monitoring. Stenosis resistance was calculated as the ratio between pressure gradient and blood flow, microvascular resistance as the ratio between distal pressure and blood flow. Measurements were obtained at baseline, following intracoronary adenosine (2 mg) and during transient ischemia. Aortic and distal coronary pressures were also measured during balloon coronary occlusion.RESULTSAdenosine did not affect stenosis resistance, while it decreased (p < 0.05) microvascular resistance to 52 ± 22% of baseline. Angina and ischemic ST segment shift were associated with transient angiographic coronary occlusion in 7 of 10 patients; however, in no case was ischemia associated with interruption of flow. Despite markedly different flow values, distal coronary pressure was similar during adenosine and during spontaneous ischemia (48 ± 15 vs. 46 ± 20 mm Hg, respectively, NS). During ischemia, a marked increase in the resistance of both coronary stenosis and coronary microcirculation was observed (to 1,233% ± 1,298% and 671% ± 652% of baseline, respectively, p < 0.05). Distal coronary pressure was markedly reduced during balloon coronary occlusion (14 ± 7 mm Hg, p < 0.05 vs. both adenosine and ischemia), suggesting the absence of significant collateral circulation.CONCLUSIONSIn patients with UA, transient myocardial ischemia is associated with vasoconstriction of both stenotic arterial segment and downstream microcirculation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.