Abstract

Although coronary artery perforation can be a fatal complication during percutaneous coronary intervention, it is rarely observed in in-stent restenotic lesions. We present a case with coronary artery perforation after balloon dilatation for a recurrent in-stent restenotic lesion with calcified nodule inside the double-layered stents that were previously implanted. (Level of Difficulty: Advanced.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.