Abstract
In this paper, computation of the corona current and, hence, the corona power loss associated with bipolar high-voltage direct current (HVDC) conductors is presented using the finite-element method (FEM) and the method of characteristics (MOC). The former method is used to solve Poisson's equation while the latter is used to satisfy the current continuity condition. The ground-plane current density and electric field profiles associated with the HVDC conductors are also calculated as a prerequisite for the computation of the corona current. The effectiveness of the present method is demonstrated using HVDC full-scale and laboratory-model transmission lines. Horizontal and vertical bipolar configurations are tested with 2 and 4 bundles. Comparison between previously measured and computed profiles and present calculations shows satisfactory agreement with previous measured and calculated values.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.