Abstract
To monitor bilateral corneal parameters after unilateral Baerveldt 350 tube-shunt implantation (Advanced Medical Optics, Santa Ana, CA) through the ciliary sulcus. Retrospective, interventional case series. Patients from 1 private glaucoma practice with severe uncontrolled glaucoma treated with sulcus tube-shunt implantation in 1 pseudophakic eye. Specular microscopy data were collected before and after unilateral sulcus tube-shunt implantation from the surgical and the glaucomatous fellow eyes. Central corneal endothelial cell density (CECD), coefficient of variation (CV), percent of hexagonal cells, central corneal thickness (CCT), intraocular pressure (IOP), IOP-lowering medications, visual acuity, and complications. Forty-six patients (mean age, 69.9 years; standard deviation [SD], 4.6 years; range, 20-88 years; male gender, 41.3%) were identified. After surgery, IOP and the number of IOP-lowering medications decreased significantly by 42.3% (P < 0.0001) and 32.1% (P < 0.0001), respectively, in the surgical eye group. Preoperative CECD measured 1807 cells/mm2 (SD, 172 cells/mm2) and 1825 cells/mm2 (SD, 172 cells/mm2) in the surgical and fellow eyes, respectively (P= 0.92), and compared with baseline, it decreased by 8.6% (P= 0.17) and 3.1% (P=0.65), respectively, by 24 months. Preoperative CV, percent of hexagonal cells, and CCT were similar in both groups and remained stable. All corneal parameters remained unchanged in a subgroup of 15 patients with low preoperative CECD (1273 cells/mm2; SD, 99 cells/mm2). Best-corrected visual acuity remained stable in bothgroups. Hyphema occurred in 23.9% of the surgical eyes and resolved with no intervention. We found no sight-threatening complications or corneal failures during follow-up. Tube-shunt implantation through the ciliary sulcus in pseudophakic eyes appears relatively safe to the corneal endothelium, demonstrating a small and nonsignificant decline in central CECD compared with baseline and with glaucomatous fellow eyes. No significant disruption to corneal endothelial cell morphologic features, increased corneal thickness, or corneal failures were found during the 24-month follow-up period. A prospective head-to-head comparison to assess the effects of the various methods of tube-shunt implantation on the corneal endothelium is needed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.