Abstract

We compared the changes in corneal endothelial cells and surgical outcomes after Ahmed glaucoma valve (AGV) implantation with the valve tip inserted either into ciliary sulcus (CS) or anterior chamber (AC). We retrospectively reviewed the medical records of patients treated with CS AGV (n = 24) and AC AGV (n = 38). We compared the preoperative and postoperative central corneal endothelial cell density (ECD), endothelial cell coefficient of variation (CV), best-corrected visual acuity, intraocular pressure (IOP), number of glaucoma medications, and postoperative complications in the two groups. Both groups had similar baseline characteristics and follow-up period. At the last follow-up, the AC AGV group had significantly higher mean monthly ECD loss (17.47 ± 11.50 cells/mm2 vs. 6.40 ± 7.69 cells/mm2, p < 0.0001) and greater proportion of mean monthly ECD loss than the CS AGV group (0.84 ± 0.53 vs. 0.36 ± 0.39%, p < 0.0001). Both groups had similar mean monthly CV changes. The qualified success rates at 2 years were 83.3% and 76.3% for the CS AGV and AC AGV groups, respectively. Although similar surgical outcomes including visual acuity, IOP, number of glaucoma medications, and postoperative complications were obtained following CS AGV and AC AGV, corneal ECD loss was higher in the AC AGV group. Thus, CS AGV may be a better surgical option than AC AGV.

Highlights

  • Joo Yeon Kim, Jihei Sara Lee, Taekjune Lee, Duri Seo, Wungrak Choi, Hyoung Won Bae & Chan Yun Kim*

  • There was no significant difference between the groups in terms of age, sex, laterality, central corneal thickness (CCT), axial length, anterior chamber (AC) depth, best-corrected visual acuity (BCVA), intraocular pressure (IOP), number of preoperative glaucoma medications, or type of glaucoma diagnosis (Table 1)

  • At the last follow-up, the mean IOP had significantly decreased from 28.37 ± 6.57 mmHg to 13.42 ± 3.19 mmHg in the ciliary sulcus (CS) Ahmed glaucoma valve (AGV) group (p < 0.0001) and from 26.00 ± 5.68 mmHg to 13.26 ± 2.51 mmHg in the AC AGV group (p < 0.0001)

Read more

Summary

Introduction

Joo Yeon Kim, Jihei Sara Lee, Taekjune Lee, Duri Seo, Wungrak Choi, Hyoung Won Bae & Chan Yun Kim*. We compared the changes in corneal endothelial cells and surgical outcomes after Ahmed glaucoma valve (AGV) implantation with the valve tip inserted either into ciliary sulcus (CS) or anterior chamber (AC). We compared the preoperative and postoperative central corneal endothelial cell density (ECD), endothelial cell coefficient of variation (CV), best-corrected visual acuity, intraocular pressure (IOP), number of glaucoma medications, and postoperative complications in the two groups. Both groups had similar baseline characteristics and follow-up period. Similar surgical outcomes including visual acuity, IOP, number of glaucoma medications, and postoperative complications were obtained following CS AGV and AC AGV, corneal ECD loss was higher in the AC AGV group. The aim of this study was to compare the effects of placing the tube in the CS or AC during AGV implantation on corneal endothelial cell loss and surgical outcomes

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.