Abstract

BackgroundStandardized corneal densitometry (CD) values in large samples of healthy Chinese individuals are scarce. Therefore, we aimed to determine the standard CD values using a Scheimpflug camera in healthy corneas, investigate the correlations of sex, age, and ocular parameters with corneal density, and explore the impact of corneal density on the forward scattering and optical quality of the eye.MethodsThis retrospective observational study involved 990 healthy Chinese individuals, including 494 males and 496 females (mean age: 23.88 ± 6.90 years). The CD values at various depths and radial areas of 0–12 mm were measured using a Scheimpflug camera. Densitometric measurements were expressed in standardized grayscale units (GSU). The optical scatter index (OSI), modulation transfer function cutoff values (MTFcutoff), and Strehl’s ratio (SR) were also determined using an optical quality analysis system.ResultsThe average CD within a 12 mm diameter area was 16.26 ± 1.35 GSU. The highest and lowest optical densities at different depths were observed in the anterior (21.41 ± 2.16 GSU) and posterior (12.00 ± 1.01 GSU) layers, respectively (P < 0.001). Similarly, the maximum and minimum optical densities at different radial areas were observed in the 10–12 mm (14.09 ± 0.93 GSU) and 2–6 mm (25.93 ± 4.77 GSU) circles, respectively (P < 0.001). There was no significant difference in the average CD within a 12 mm diameter area between males and females (P > 0.05). However, upon adjusting for age, central corneal thickness (CCT), corneal curvature, white-to-white (WTW) corneal diameter, and axial length, females exhibited a greater average CD within the 12 mm diameter and in the 6–10 mm and 10–12 mm circles than males. Age-related changes in CD were evident, except in the 2–6 mm circle. CCT, corneal curvature, WTW corneal diameter, and partial depth correlated with CD in the radial area, and CD in different areas correlated with the OSI, MTFcutoff, and SR (P < 0.05).ConclusionsThis study provides the normative CD measurement data of Chinese adults with healthy corneas, emphasizing the significance of sex, age, CCT, corneal curvature, and WTW corneal diameter in CD evaluation. Notably, elevated CD can lead to increased forward scattering within the eye, thereby affecting the optical quality.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.