Abstract

Corneal damage thresholds were determined in Dutch Belted rabbits following CO2 laser radiation with pulse widths of 1.7, 25 and 250 ns. The threshold values for corneal clouding found for the 3 cases were 0.33, 0.54 and 0.18 J/cm2, respectively. These results are in accord with expectations based on a thermal-damage mechanism, with no evidence of acoustic shock or other mechanisms contributing to the observed damage for the exposure parameters used in this study. The data support the suggested maximum permissible exposure levels for short-pulse far-infrared laser radiation as quoted in current laser safety standards.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.