Abstract

This paper undertakes an analysis of the causes of core vibration in Si-Fe distributed gap wound cores, based on appropriate exploitation of calculated and experimental local flux distributions, intending to propose techniques enabling reduction of the resulting noise. Magnetostriction phenomenon effects, playing an important role in the noise level, can be handled by using appropriate lamination geometry optimization and low stress core building. The magnetic forces in the lap-joint regions, constituting another significant source of vibration, can be reduced by conveniently increasing the clamping pressure. However, special attention has to be paid in optimizing clamping pressure increase, as it accentuates magnetostriction. Finally, it was assessed that the in-plane lamination magnetic forces do not significantly affect core vibrations, at least in the considered core case, corresponding to a typical wound core type distribution trans former.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.