Abstract

In the reactor safety assessment during reflood phase of a PWR-LOCA, it is assumed implicitly that the core thermal hydraulic behavior is evaluated by the one-dimensional model with an average power rod. In order to assess the applicability of the one-dimensional treatment, integral tests were performed with various core radial power profiles using the Cylindrical Core Test Facility (CCTF) whose core includes about 2,000 heater rods. The CCTF results confirm that the core radial power profile has weak effect on the thermal hydraulic behavior in the primary system except core. It is also confirmed that the core differential pressure in the axial direction is predicted by the one-dimensional core model with an average power rod even in the case with a steep radial power profile in the core. Even though the core heat transfer coefficient is dependent on the core radial power profile, it is found that the error of the peak clad surface temperature calculation is less than 15K using the one-dimensional model i...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.