The core losses of an interior permanent magnet synchronous motor have been reduced by about 38 % by using an amorphous magnetic material stator core instead of a non-oriented steel stator core. Numerical calculation and experimental tests data have been compared to evaluate the reliability of the results. The amorphous magnetic material stator core has been realized using the latest improvements in manufacturing technologies.