Abstract
Due to the harmonic content of the distorted supply voltage, the iron losses of PWM inverter fed induction motors are greater than the iron losses measured with sinusoidal supply. The prediction of this loss increase has been the subject of many studies, but it can be still considered as an open research field, in particular when fast and reliable estimation methods are requested. In the paper a previously developed method to predict the iron losses with PWM supply in magnetic laminations (using toroidal samples or the Epstein frame) and special induction prototypes (with a plastic squirrel cage) has been now used to predict the iron losses of five industrial induction motors with aluminum die cast rotor cages. The measured iron loss values have been collected by means of the conventional no-load test, both under sinusoidal and PWM supply conditions. The reported analyses and comments allow a critical discussion of the proposed estimation method and of the no-load test under PWM supply.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.