Abstract
The work presents a fast and accurate core loss evaluation method for inverter-fed induction machines. The proposed method takes into account the influence of time variation of magnetic permeability on the eddy current loss. Furthermore, the proposed method presents an accurate approach to precisely evaluate the hysteresis loss. The results obtained from the proposed method are compared with the existing methods for a 1.5kW inverter-driven induction motor. The method shows sufficiently high accuracy with reduced complexity and implementation-time for a wide range of inverter switching frequency and motor's loading.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.