Abstract

The profiles of ac hysteresis loops have been measured as function of the angle Φ between H-field and [001] axis in (110)[001] grain oriented 3% silicon-iron. As Φ increases, for Φ≥30° the loop changes into a wasp-waisted shape with inflection points. The observed ac hysteresis loop profiles have been analyzed in terms of domain reorientation under field. The core losses in silicon-iron are measured for various magnetizing angles with respect to the easy axis at magnetizing frequency 50 Hz and 60 Hz and at magnetic induction 1.3 T and 1.0 T. At magnetic induction 1.3 T, the core loss increased to near 70° and decreased at magnetizing frequency 60 Hz, but at 50 Hz this trend was different from 60 Hz and the core loss was monotonously increased.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.