Abstract

In order to reduce copper loss, high step-down DC-DC converter often employs center-tapped rectifier. In addition, a plate shape one turn coil is utilized for transformer for making a high step-down ratio. We focused on the proximity effect in plate shape one turn coil, and investigate the cause of worsening the copper loss. In this paper, based on this investigation, we propose rectification method using winding integrated with rectifier. In addition, we discuss practical issues of the proposed method and present the solution strategy. The proposed method is verified by experiments, which suggests the effectiveness of the proposed method to high current applications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.