Abstract

The paper presents a laser monitor with 10μs time-resolution based on a high-frequency copper bromide vapor brightness amplifier. A sync circuit has been designed for single-pulse imaging. The analysis of amplifying characteristics of the active elements and active optical system (laser monitor) parameters allowed to determine the optimal concentration of HBr at which the images can be obtained with minimum distortions. For the active element operating at high frequencies (more than 50kHz) as a brightness amplifier, the concentration of HBr must be lower than that needed for obtaining the maximum output power. The limiting brightness temperature of the background radiation which does not affect the image quality is determined. The potential feasibility of using a proposed brightness amplifier for visualizing processes blocked from viewing by the background radiation with the brightness temperature up to 8000K is demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.