Abstract

The integration of increasing share of renewable based distributed generation in distribution networks brings great challenges to voltage control. To address this issue, this paper presents a two-stage distributionally robust chance-constrained receding horizon control algorithm. In the proposed method, the distributionally robust chance-constrained reformulation of chance-constrained voltage control is derived, which is not only accurate, but also computationally efficient. Rather than perfect knowledge about the uncertainty associated with renewable generation, the proposed method only requires partial information of the underlying probability distribution. In addition, the mechanical voltage regulation devices and the DG inverters are controlled in two stages, considering their different characteristics in voltage control. By taking into account both the current and forecasted renewable generation, the proposed method utilizes receding horizon control to determine the control actions of voltage regulation devices. The effectiveness of the proposed method is demonstrated by case studies on unbalanced IEEE-123 bus system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.