Abstract
The wake effect reduces the wind speed at downstream wind turbines (WTs), making it necessary for the central controller to collect wind power generation data from each WT. However, wind farms (WFs) face a more complex problem in maintaining the voltage stability at the WT terminal while following the transmission system operator (TSO) instructions due to the information collection as well as the possible data loss during transmission. Therefore, this study proposes a coordinated control method for WTs and multiple power sources based on model predictive control under wake disturbance conditions, aiming to reduce the average voltage deviation in WT terminals and go close to the rated voltage and ensure effective compliance with TSO commands in large-scale WFs. Accordingly, the Jensen wake model was utilized to accurately calculate the available active and reactive power limits for each WT. Energy storage systems and static Var generators were modeled to coordinate and maintain the voltage in all WT terminals within the feasible range, providing peak shaving and valley filling support to reduce wind energy waste and shortfall, thereby enhancing the economic and operational reliability of WF. Further, the effectiveness of the proposed method was validated in MATLAB/Simulink.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.