Abstract

There is a risk of wind turbine stalling when virtual inertial response is provided during low wind speeds due to the turbine speed reduction. Therefore, it is wise to consider minimum rotor speed limitation during inertial response provision so it can be suspended in time to avoid stalling. However, since low wind speed conditions can happen fairly often, the capability for inertial response is lost which may be crucial for scenarios with high wind penetration. On the other hand, during above rated wind speeds, generator and converter maximum current limit the amount of extra power that can be injected. In this paper, we present a coordinated control of a wind turbine and an ultracapacitor bank to provide inertial response during both low and above rated wind speed conditions. The developed algorithm is implemented in DIgSILENT PowerFactory and tested in a standard IEEE 9-bus test system. Results show superiority of the proposed method compared to the approach when only wind turbine generators are participating in virtual inertial response.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.