Abstract

We studied cooling strategy in a square enclosure with ventilation ports and a discrete heat source at its optimum position. We searched the optimum heater position by maximizing the global conductance at different Rayleigh and Reynolds numbers and considered three different ventilation ports arrangements. We solved the conservation equations of mass, momentum and energy for mixed convection. We found that the heater position is at off center in all cases, its optimum position is insensitive to the variation of Ra and Re; it solely depends on the ventilation ports arrangement. The Nusselt number is dependent on Ri = Ra/ Re 2: at its low values, Nu is a decreasing function of Ri and at its high values, it is an increasing function of it.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.