Abstract
In order to study the juice cooling process after sterilization to obtain the accurate process and reduce the energy used in the cooling, the orange juice in can high temperature short time (HTST) sterilization process was calculated. The maximum temperature of juice in can was defined as 60°C. By using FLUENT, a kind of software which combines hydrodynamics, mathematics and computer technology, we were able to put different fluids into analog computation and numerical experiment to solve problems related to hydrodynamics. Orange juice cooling numerical experiment after HTST sterilization was carried out. The optimization cooling process was obtained: 20°C(293K),14 minutes;15°C(288K),13 minutes; 10°C(283K) ,13minutes; 5°C(278K), 12minutes and 0°C(273K), 12minutes. Using Carnot efficiency in Reverse Carnot cycle, the energy consumption was: 288W, 325W, 348W, 391W, 417W in accordance. And in the result, the optimized process was : 20°C(293K),12 minutes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.