Abstract

The cooling characteristics of an impinging spray jet which forms an ellipsoidal liquid film were experimentally investigated in order to estimate the cooling performance of a rotating roll in a hot mill system. The following four conclusions were reached in the study. (1) In the case of a single spray jet, the local heat transfer coefficient at the center position depends on the forced convective heat transfer by the impinging jet. However, the average heat transfer coefficient is proportional to the flow rate density of the cooling water, and it does not depend on the distance between the nozzle and heated surface. (2) In the case of a double spray jet, liquid film interference occurs. The local heat transfer coefficient at the center position is greater, and the cooling performance increases with the increasing flow rate density of the cooling water. (3) The cooling performance of a multispray jet is proportional to the flow rate density of the cooling water. It does not depend on the nozzle construction, distance, or specifications. Also, there is no relation to the liquid film interference. (4) When the optimum specifications of the spray nozzle are used, thermal analysis of a rotating roll shows that the temperature at a depth of 1.3 mm from the surface is below 130 °C. © 2000 Scripta Technica, Heat Trans Asian Res, 29(4): 280–299, 2000