Abstract

Methods used to convert wind tunnel and ADMS concentration field data for a complex building array into effective radiation dose were developed based on simulations of a site in central London. Pollutant source terms were from positron emitting gases released from a cyclotron and clinical PET radiotracer facility. Five years of meteorological data were analysed to determine the probability distribution of wind direction and speed. A hemispherical plume cloud model (both static and moving) was developed which enabled an expression of gamma-ray dose, taking into account build-up factors in air, in terms of analytic functions in this geometry. The standard building wake model is presented, but this is extended and developed in a new model to cover the concentration field in the vicinity of a roof top structure recirculation zone, which is then related to the concentration in the main building wake zone. For all models presented the effective dose was determined from inhalation, positron cloud immersion and gamma ray plume contributions. Results of applying these models for determination of radiation dose for a particular site are presented elsewhere.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.