Abstract

BackgroundIpsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required.Case presentationA 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work.ConclusionConversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call