This paper proposes a way to assess total electric field strength by using mono-axial probe (instead of isotropic, tri-axial probe). When mono-axial probe is used, additional conversion factor should be applied. Consequently, the usage of mono-axial probe causes additional uncertainty in measurement results that should be taken into account. Measurement results for seven different environments show that the additional multiplicative conversion factor value of 1.95 should be applied and additional uncertainty in measurement results of 33.07 % should be taken into account.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.