Abstract

For a single-phase distribution network with constant-power, constant-current, and constant-impedance loads (ZIP loads), sufficient conditions are presented that explicitly define a region where a unique load-flow solution exists. The Z-Bus method is shown to be a contraction mapping iteration, which upon initialization within this region, is guaranteed to converge to the unique load-flow solution. The sufficient conditions for convergence of the Z-Bus method are numerically verified for IEEE distribution test feeders.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.