Abstract

PurposeTo evaluate if Field of view Optimized and Constrained Undistorted Single shot (FOCUS) (GE Healthcare, Waukesha, WI) diffusion weighted images (DWI) provide more reliable imaging than conventional DWI, with non-inferior quantitative apparent diffusion coefficient (ADC) results. Material and methodsIRB approval was obtained for this study of 43 patients (44 exams, one patient with two visits) that underwent multiparametric prostate MRI with two DWI sequences and subsequent radical prostatectomy with histology as the gold standard. Randomized DWI sequence images were graded independently by two blinded experienced prostate MRI radiologists with a period of memory extinction between the two separate reading sessions. Blinded images were also reviewed head to head in a later session for direct comparison. Multiple parameters were measured from a region of interest in a dominant lesion as well as two control areas. Patient characteristics were collected by chart review. ResultsThere was good correlation between the mean ADC value for lesions obtained by conventional and FOCUS DWI (ρ=0.85), with no trend toward any systematic difference, and equivalent correlation between ADC measurements and Gleason score. Agreement between the two readers was significantly higher for lesion ROI analysis with the FOCUS DWI derived ADC values (CCC 0.839) compared with the conventional ADC values (CCC 0.618; difference 0.221, 95% CI 0.01–0.46). FOCUS showed significantly better image quality scores (separate review: mean 2.17±0.6, p<0.001) compared to the conventional sequence (mean 2.65±0.6, p<0.001). In 13 cases the image quality was improved from grade of 3+ with conventional DWI to <3 with FOCUS DWI, a clinically meaningful improvement. Head-to-head blinded review found 61 ratings showed strong to slight preference for FOCUS, 13 no preference, and 14 slight preference for the conventional sequence. There was also a strong and equivalent correlation between both sequences and PIRADS version 2 grading (ρ=−0.56 and −0.58 for FOCUS and conventional, respectively, p<0.001 for both). ConclusionFOCUS DWI of the prostate shows significant improvement in inter-reader agreement and image quality. As opposed to previous conflicting smaller studies, we found equivalent ADC metrics compared with the conventional DWI sequence, and preserved correlation with Gleason score.In 52% of patients the improved image quality with FOCUS had the potential to salvage exams with otherwise limited to non-diagnostic DWI.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.