Abstract

Abstract Introduction/Background Leadless ventricular permanent pacemakers (leadless VVI, LPM) were designed to reduce lead-related complications of conventional VVI pacemakers (CPM). Purpose The aim of our study was to assess and compare real-life clinical outcomes within the first 30 days and during a mid-term follow-up with the two techniques at a nationwide level. Methods This French longitudinal cohort study was based on the national hospitalization database covering hospital care from for the entire population. All adults (age ≥18 years) hospitalized in French hospitals From January 1, 2017 to September 1, 2020, who underwent a first LPM or CPM implantation were included. Importantly, patients with dual chamber pacemaker were not included in our study. Results Of 42,315 patients included in the cohort, 40,828 patients (96%) had a CPM and 1,487 had a LPM. Using propensity score, 1,344 patients with CPM were adequately matched in a 1:1 fashion with LPM patients. Clinical outcomes at day 30 In the unmatched population, within the 30 days after implantation, patients with LPM had a lower rate of all-cause mortality (OR: 0.635, 95% CI: 0.527–0.765, p<0.0001) and from a cardiovascular cause (OR: 0.568, 95% CI: 0.405–0.797, p=0.001). They also had lower rates of major bleeding and need for transfusion. There was no significant difference between groups regarding tamponade, pneumothorax or hemothorax. In the matched population, LPM implantation was still significantly associated with a lower rate of all-cause death (OR: 0.583, 95% CI: 0.456–0.744, p<0.0001), cardiovascular death (OR: 0.413, 95% CI: 0.271–0.629, p<0.0001), major bleeding (OR: 0.523, 95% CI: 0.348–0.786, p=0.002) or transfusion (OR: 0.481, 95% CI: 0.296–0.780, p<0.0001). However, tamponade, pneumothorax or hemothorax were not significantly different between the two groups. Clinical outcomes during mid-term follow-up In the unmatched patients, mean follow-up was 8.6±10.5 months. Annual incidence of all-cause death was high in both groups, and significantly higher in the LPM group than in CPM group (31%/year vs. 20%/year, p<0.0001) with a HR of 1.519 (95% CI: 1.296–1.780). Cardiovascular death was not significantly different between groups. Infective endocarditis was higher in the LPM group than in the CPM group with a HR of 2.108 (95% CI: 1.119–3.973). In the matched patients, mean follow-up was 6.2±8.7 months. All-cause death, cardiovascular death and infective endocarditis were not significantly different between groups. Conclusion Mortality is high among unselected patients implanted with ventricular permanent pacemakers, whether leadless or conventional pacemaker are used. Implantation of leadless pacemakers seems to be a safe procedure in this high-risk population, with better outcomes at 1 month. Mid-term outcomes appear relatively similar in LPM and CPM patients. Funding Acknowledgement Type of funding sources: None. Central illustration

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call