Abstract

To evaluate the diagnostic power of conventional, achromatic, automated perimetry (CAP), short-wavelength automated perimetry (SWAP), frequency-doubling technology (FDT) perimetry, and visual evoked potentials (VEP) in a group of patients with multiple sclerosis (MS) with or without a history of optic neuritis. Thirty eyes of 15 patients (5 male, 10 female, average age 38+/-7 years) with confirmed diagnosis of MS underwent CAP, SWAP (Humphrey 750-II VFA, program central 30-2, full-threshold strategy), FDT perimetry (program N-30), and pattern VEPs. Sixteen eyes (53.3%) had no history of ocular involvement and a negative ophthalmologic examination. They were matched with a control group of 10 healthy volunteers (4 male, 6 female, average age 31+/-10 years). The mean deviation (MD) and the pattern standard deviation (PSD) of the two groups were compared (t-test). Fourteen eyes (46.7%) had, on the contrary, a history of optic neuritis. Inside this group, the MD and the PSD of the three techniques were correlated (Spearman's rank test), in order to investigate whether any significant differences might be revealed by these techniques in pointing out the total amount of visual field damage. When comparing MS patients without signs or symptoms of ocular involvement and a control group, no significant differences were found for CAP MD, CAP PSD, and FDT PSD. Significant differences were found, on the contrary, for SWAP MD (p=0.0014), SWAP PSD (p=0.0001), and FDT MD (p=0.0001). When considering the MD and the PSD of the three techniques in the group of MS patients who had a history of optic neuritis, a significant correlation was found only between CAP MD and SWAP MD (r=0.0057), with a tendency by SWAP to reveal a higher rate of visual field loss. The other correlations were not significant. According to predefined criteria, the group of asymptomatic subjects had abnormal CAP in 1 eye (6.25%), abnormal SWAP in 9 (56.2%), abnormal FDT in 11 (68.7%), and abnormal VEPs in 7 (43.7%). The combined use of all techniques allowed us to identify silent optic nerve impairment in 15 (93.7%) eyes. Short-wavelength automated perimetry and FDT perimetry are two non-conventional perimetric techniques that were mainly developed for the early detection of glaucomatous damage. The results of this study demonstrate their efficacy also in detecting early visual field deficits in MS patients without clinical signs of optic neuropathy. Frequency doubling perimetry, in particular, proved to be an easy, fast, and sensitive technique in the assessment of patients with MS. Our results also suggest that subclinical visual involvement in MS can be better diagnosed using multiple (neurophysiologic and psychophysical) tests.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.