Abstract

In this article, experiments are carried out in a hypersonic shock tunnel with helium as driver gas and air as the test gas to obtain the convective heating rate and surface pressure distribution on a cone model placed at hypersonic speed. Test is performed in hypersonic shock tunnel for a flow Mach number of 6.5 at two different angles of attack, 0° and 5°. The sputtered thin film platinum sensors are used to measure the heat flux on a cone model. The measured heat-transfer rate compares well with theoretically estimated values using reference enthalpy method and computational fluid dynamics (CFD) simulation. The measured surface pressure compares well with CFD.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call