Abstract
This paper studies the influence of secondary heat sources on the convective heat transfer from a vertical cylindrical heater immersed in a LIN pool. Two types of secondary heat source have been used. In the first case, the heat leak through the vessel walls into the pool was varied without causing nucleation, so as to retain convective heat transfer. It was found that the convective flow loops induced in the pool produced a small enhancement of the heat transfer from the cylindrical heater. In the second case, a small horizontal heater loop was introduced into the pool below the cylindrical heater. The secondary heat flux used was such that boiling occurred at the loop to give rising bubbles surrounding the cylindrical heater. This produced a large enhancement of the convective heat transfer from the cylindrical heater. The enhancement ratio is presented as a function of the power supplied to the loop heater.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.