Abstract

This paper proposed a structural measure according to add batten sheets between two lips to controlling distortional buckling of cold-formed thin-walled steel members with lipped channel section, and the effectiveness was verified through existing tests. At the same time, the stiffness requirements of batten sheets were presented. The structural measures of adding batten sheets between two lips can effectively prevent the rotation of partially stiffened elements, and the distortional buckling load and bearing capacity of the members have been greatly improved. The test shows that the batten sheets with a certain distance and stiffness can improve the bearing capacity of the member or avoid the occurrence of distortional buckling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.