Abstract
Rapid right ventricular pacing is safe, effective, and established method to provide balloon stability during balloon aortic valvuloplasty (BAV). Controlled transient respiratory arrest at this point of time may further reduce left ventricular stroke volume, providing an additional benefit to maintain balloon stability. Two groups were studied. Among the 10 patients, five had rapid pacing alone (Group A), while the other five were provided with cessation of positive pressure breathing as well (Group B). The outcomes of BAV in the two groups of patients were studied. One patient in Group A had failed balloon dilatation even after the fourth attempt, while in Group B there were no failures. The peak systolic gradient reduction was higher in Group B (70.05% in comparison to 52.16% of group A). In Group A, five subjects developed aortic regurgitation (grade 2 in four and grade 3 in one, while no grade 3 aortic regurgitation developed in any patient in Group B). Controlled transient respiratory arrest along with rapid ventricular pacing may be effective in maintaining balloon stability and improve the outcome of BAV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.