Abstract

Various nanoscale fabrication techniques are elaborated to form artificial nanoporous/nanochannel membranes to be applied for biosensing: one of the most prevalent is the micro-electromechanical systems (MEMS) compatible focused ion beam (FIB) milling. This technique can be easily adopted in micro- and nanomachining process sequences to develop composite multi-pore structures, although its precision and reproducibility are key points in the case of these thick multi-layered membranes. This work is to demonstrate a comprehensive characterisation of FIB milling to improve the reliability of the fabrication of solid state nanopore arrays with precisely predetermined pore geometries for a targeted molecule type to be recognised. The statistical geometric features of the fabricated nanopores were recorded as the function of the process parameters, and the resulting geometries were analysed in detail by high resolution scanning electron microscope (SEM), transmission electron microscope (TEM) and ion scanning microscopy. Continuous function of the pore diameter evolution rate was derived from the experimental results in the case of different material structures, and compared to former dissentient estimations. The additional metal layer was deposited onto the backside of the membrane and grounded during the ion milling to prevent the electrical charging of dielectric layers. The study proved that the conformity of the pore geometry and the reliability of their fabrication could be improved significantly. The applicability of the developed nanopore arrays for molecule detection was also considered by characterising the pore diameter dependent sensitivity of the membrane impedance modulation based measurement method.

Highlights

  • Compared to the macroscopic case, self-confined nanoscale structures exhibit significantly different chemical and transport behaviours

  • Solid state nanopores were prepared by computer controlled Focused Ion Beam (FIB) milling using accelerated Ga+ ions with different milling currents and doses, in order to achieve various pore geometries in multi-layered membranes made of different dielectrics

  • The evolving pore diameter depends on the material composition, and the thickness of the membrane, as well as on the applied milling time, ion dose, current and energy

Read more

Summary

Introduction

Compared to the macroscopic case, self-confined nanoscale structures exhibit significantly different chemical and transport behaviours. The understanding of the involved chemical and physical phenomena opens the way to explore the “world of nanofluidics” [1], and to develop brand new sensing principles on the molecular or sub-molecular level

Transport in Nanoscale
Applications of Nanofluidic Systems
Materials and Methods
FIB Process Development
Pore size Dependent Sensitivity of Molecule Detection
Conclusions