Abstract

The expedient field disposal of excess gun propellants on the ground is an integral part of live-fire training in many countries. However, burning excess propellant in the field will leave significant quantities of energetic residues and heavy metals in the environment. Compounds such as dinitrotoluene and nitroglycerin and metals such as lead will leach into the soil column, eventually migrating to groundwater. Contamination of the environment will lead to high remediation costs and the possible loss of the training facility. After investigating the contamination at several propellant disposal sites, a portable propellant burn pan was developed and tested. The pan was transported to training sites where excess propellant was loaded and burned in a controlled manner. Up to 120kg of excess single-base propellant charges have been burned during two series of tests at a consumption rate of greater than 99.9%. Less than 0.03% of the energetic material was recovered outside the burn pan. Recovered lead is largely contained within the pan. The turnover rate for burns is 15min. The residues can be collected following cool-down for proper disposal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.