Abstract

In this report, an ocular device for the controlled delivery of pilocarpine was evaluated in albino rabbits using miosis as a bioassay for efficacy. The device was fabricated using Gelfoam® (absorbable gelatin sponge, USP) in the form of a matrix system. The efficacy of the device was compared in a cross-over study to the two conventional ophthalmic pilocarpine dosage forms, the eyedrop and the gel. The in-vivo results show that the gelfoam device is more effective than the two conventional pilocarpine dosage forms in prolonging the duration of the pilocarpine activity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.