The prime role of a renewable resource based DC hybrid power system is, to maintain the output voltage constant with higher efficiency. In order to achieve this the duty cycles of the converter switches are dynamically controlled. Multiple input single output (MISO) converter uses separate controller for adjusting the duty cycle, this complicates the design and implementation of the system. Hence, to overcome this limitation a centralized controller is used. The control strategy depends on the pattern of gating signals given to the converter switches. When independent controller is employed, then gating signals of any pattern can be used to drive the switches. However, if a single controller is used, and then a definite pattern is very much essential otherwise, the output voltage and efficiency gets affected. In this paper, an attempt is made to validate and evaluate the performance parameters of MISO converter with two pattern of gating signals; they are synchronized and unsynchronized pulses at their rising edge. The control strategy focusses on the generation of these gating pulses. PID controller is tuned appropriately to determine the gains to achieve the stability of the proposed converter. The dual input power converter validated to show how the PWM pattern affects the efficiency, ripple and regulation of the converter. Using MATLAB SIMULINK platform the simulation of the proposed concept with dual input converter in closed loop is validated. Simulation results proves that synchronized pulses gives DC efficiency of 87% at designed output of 12V output. Converter with unsynchronized PWM pulses operates at lesser efficiency of 75% and the output voltage is of 10V.

Highlights

  • One of the performance parameters of DC-DC converter is the regulation of output voltage.There are many techniques that are employed to control the output voltage of converters, but it is always in demand for many industrial applications to have a simple and low cost controller structure

  • The control strategy employs two PWM generators to produce two gating pulses that are out of phase to regulate the output voltage. This technique is simple in implementation and the results shows that the output voltage is regulated at 12V but the proposed strategy transfers power to load independently but fails to transfer simultaneously

  • In this paper conventional proportional integral derivative (PID) controller in voltage control mode is chosen for dual input SEPIC converter with synchronized and unsynchronized gating pulses

Read more

Summary

INTRODUCTION

One of the performance parameters of DC-DC converter is the regulation of output voltage.There are many techniques that are employed to control the output voltage of converters, but it is always in demand for many industrial applications to have a simple and low cost controller structure. The control strategy employs two PWM generators to produce two gating pulses that are out of phase to regulate the output voltage This technique is simple in implementation and the results shows that the output voltage is regulated at 12V but the proposed strategy transfers power to load independently but fails to transfer simultaneously. To address this issue, in this paper conventional PID controller in voltage control mode is chosen for dual input SEPIC converter with synchronized and unsynchronized gating pulses. One of the duty cycle is fixed and the other was varied to regulate the output voltage Both the mechanism are not very effective for all conditions.

Time in secs
ΔVo volts
Findings
CONCLUSION

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.