Abstract

Due to poor quality of grid-connected current and large impedance value of grid are caused in weak grid environment. Therefore, a control strategy combining multiple resonant feedforward and current estimation method is adopted in this paper. Firstly, in order to make the positive feedback channel have the feedback effect only at the main background harmonics, the low-order harmonics of the grid are extracted by using the method of multi-resonance feedforward control. At the same time, under the premise that the suppression effect of LCL natural resonant frequency remains unchanged, the current estimation method is added into the control strategy, so as to reduce the system cost. Finally, the simulation results show that thus verifying the correctness and effectiveness of the control strategy.