Abstract

This study presents a novel control strategy for a five-leg inverter-fed dual three-phase permanent-magnet synchronous motor (DT-PMSM)system. Three different five-leg inverter topologies (operating modes) can be reconfigured by choosing a pair of phases for sharing the common leg. The five-leg inverter operation mode with 150° phase difference can achieve full torque output, but the utilization of DC bus voltage is low. The operation mode with 30° phase difference has higher DC bus voltage utilization but lower output torque. The modified double zero-sequence injection (DZI) PWM strategy based on carrier-based PWM (CBPWM) for five-leg inverter operating modes is proposed. This strategy can achieve the maximum DC bus voltage utilization. The five-leg inverter operating modes can be used as a fault-tolerant solution for the occurrence of a fault in one leg of the six-leg inverter. Compared with the commonly used open phases fault-tolerant control (FTC) strategies, this strategy has the advantages of without increasing the stator copper, reducing the torque ripples, and implementing easily. Experimental results verify the effectiveness and feasibility of the proposed strategy.

Highlights

  • Multiphase machines enjoy the advantages of low voltage high power, low torque pulsation and good fault tolerant ability [1]–[3]

  • Apart from the modified double zero-sequence injection (DZI) PWM strategy, there is no difference in the control strategy of the five-leg inverter and the six-leg inverter

  • EXPERIMENTAL RESULTS In order to verify the effectiveness of the five-leg control strategy in this paper, an experimental verification is carried out on a surface-modified dual three-phase permanent-magnet synchronous motor (DT-PMSM)

Read more

Summary

INTRODUCTION

Multiphase machines enjoy the advantages of low voltage high power, low torque pulsation and good fault tolerant ability [1]–[3]. They have good application prospects in high-power driving applications such as electric vehicles, marine electric propulsion, and wind power generation. Zhou: Control Strategy for a Five-Leg Inverter Supplying Dual Three-Phase PMSM devices [21]–[31]. Three different five-leg inverter topologies (operating modes) have been studied for the dual three-phase machine, and the performance indexes are compared with the six-leg inverter healthily operation and the open-phase fault-tolerant operation.

THE MODEL OF DT-PMSM
DC BUS VOLTAGE UTILIZATION ANALYSIS
EXPERIMENTAL RESULTS
CONCLUSION
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call