Abstract
This research paper presents the performance evaluation of the direct power control (DPC) and direct torque control (DTC) and doubly fed induction generator (DFIG) connected to the grid systems. Based on the designing procedure and mathematical description of DTC and DPC, the performances of DFIG in grid are analyzed using PSCAD software. In the simulation results, % pulsation of Te, PDFIG, QDFIG and % THD values of is and ir with DFIG controllers are analysed at network disturbance. And also harmonic analysis of is and VGRID are analysed in the interconnected grid system. With the stepped up speed, Vs is magnified from its rated value. But, controlling of RSC is achieved by rotor current in dq+ and dq− frames through ejsl and ejs. So, the pulsation of torque Te is 2.5% less than resonant controller. In the DTC control technique, during the stepping up of the wind speed, the pulsation rating of DFIG parameters is controlled by controlling Te. But in DPC, the stator current and voltage, gird voltage and current controls the converters of DFIG.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.