Abstract
Single-phase inverters are widely used in different renewable energy applications. Although the full-bridge inverter istypically used, dual-buck inverters provide an important advantage, since they eliminate the shoot-through problems. However, solutions proposed in the literature require additional inductors, use linear controllersdesigned around an operation point, or cannot be used in grid-connected applications. This paper presents a hysteresis current control of a single-phase dual-buck full-bridge inverter for grid-connected active power injection. Includes the dynamical modelin state variables, as well as analytical conditions to guarantee the evolution of the error dynamics in a set with boundaries defined by the designer. Moreover, the paper provides guidelines for the design of the dead band required for the transitions between the positive and negative semi-cycles (and vice-versa) of the grid voltage. Finally, simulation results validate the main features of the controller as well as the design of the dead band
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.