Abstract
The open-loop gainG0 reference pressureP0 and basal heartrateR0 of the blood-pressure regulatory system have been estimated under four different experimental conditions by employing an aortic balloon and assuming a theoretical approach based on a 1st-order linear model. Mean values of 1·7–3·7, 75–130 mmHg, and 95–130 beats/min were obtained forG0,P0 andR0, respectively. Significant variations in these parameters were observed when the anaesthetic conditions were changed. It is suggested thatG0,P0 andR0 may have useful clinical applications both in characterising hypotensive and hypertensive syndromes and also in assessing the effect of anaesthetic agents.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.