Abstract

AbstractSubsonic wind tunnel experiments were conducted to study the effect of forced transition on the pressure distribution in the concave portion of contraction. Further more, the effect of early transition on the turbulence level in the test section of the wind tunnel is studied. Measurements were performed by installing several trip strips at two different positions in the concave portion of the contraction. The results show that installation of the trip strips, have significant effects on both turbulence intensity and on the pressure distribution. The reduction in the free stream turbulence as well as the wall static pressure distribution varied significantly with the location of the trip strip. The results confirm the significant impact of the tripped boundary layer on the control of adverse pressure gradient. The trip strip at X/L = 0.115 improves pressure distribution in contraction and reduces turbulence intensity in the test section, considerably.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.