Abstract

This paper proposes a hysteresis current control method for the grid-connected quasi Z source inverter with three states and constant frequency. The hysteresis band of the inverter is analyzed in detail, and the shoot-through is inserted into the zero state without affecting the grid-connected control. Moreover, the operating states of the switches are discussed. Finally, the feasibility of the proposed topology is verified by simulations and experiments results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.